210
Error Log Section 8-3
03C2 FINS/TCP packet discarded 01 to 10:
Connection
number
02:
Reopened
because
remote node
closed
03:
Reopened
because of
reception
error
04:
Reopened
because of
transmission
error
05:
Reopened
because RST
received from
remote node
06:
Reopened
because of
no keep-alive
response
Have the FINS/TCP connection
status checked when a
SEND(090), RECV(098), or
CMND(490) instruction is exe-
cuted in the ladder program.
---
07: Illegal
FINS/TCP
procedure
Refer to Operation Manual, Con-
struction of Applications: SEC-
TION 7, and correct the remote
node (application on a personal
computer).
---
08: Insuffi-
cient mem-
ory during
server pro-
cessing
09: Insuffi-
cient mem-
ory during
client pro-
cessing
0A: Insuffi-
cient mem-
ory during
node switch-
ing
There is too much load (traffic) on
the Ethernet Unit. Correct the sys-
tem so that traffic is not concen-
trated.
---
03C3 FINS/UDP packet discarded 00 01 to FE:
Transmission
source node
address
The automatic generation (static)
method was used as the IP
address conversion method, so
remote IP address information in
internal memory could not be
changed.
---
Error
code
Meaning Detailed error code Correction EE-
PROM
1st byte 2nd byte

Table of Contents

Other manuals for Omron CS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CS Series and is the answer not in the manual?

Omron CS Series Specifications

General IconGeneral
BrandOmron
ModelCS Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals