E3X-DA-N
Connection
Connection with K3NX-VD2@ Process Meter
Nomenclature
Amplifiers
Standard, Monitor-output, Mark-detecting, Infrared, and Water-resistant Models
Twin-output Models
12 to 24 VDC
12 VDC, 80 mA*
0 V Blue
+V Brown
Monitor output Orange
E3X-DA-N
K3NX-VD2@
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17
Note 1. Various I/O Units are available for the K3NX. Select an
appropriate output type depending on the application.
2. This wiring is for the K3NX with DC power supply
specifications and the Monitor (Analog) Sensor with DC
power supply specifications. Check respective power
supply specifications before wiring.
* Use this service power supply for the Sensor with reference to the
power consumption of each Sensor.
Level DisplayLock Button
Setting Buttons
TEACH
MODE
Operation Indicator
ON when output is ON.
OFF when output is OFF.
Operating Mode Selector
Use to switch between Light ON and Dark ON modes.
Mode Selector
Use to select SET, ADJ, or RUN mode.
Level DisplayLock Button
Setting Buttons
TEACH
MODE
Mode Selector
Use to select SET, ADJ, or RUN mode.
Channel-selection Switch
Use to switch between channels 1 and 2.
Operation Indicator
ON when output is ON.