E3X-DA-N
Ratings and Specifications
Amplifiers
Pre-wired Amplifiers
Type
Standard
models
Monitor-
output
models
Mark-detecting models
Infrared
models
Water-
resistant
models
Twin-output
models
Output
type
NPN
output
E3X
-DA11-N
E3X
-DA21-N
E3X
-DAB11-N
E3X
-DAG11-N
E3X
-DAH11-N
E3X
-DA11V
E3X
-DA11TW
Item
PNP
output
E3X
-DA41-N
E3X
-DA51-N
E3X
-DAB41-N
E3X
-DAG41-N
E3X
-DAH41-N
E3X
-DA41V
E3X
-DA41TW
Light source
(wavelength)
Red LED (660 nm)
Blue LED
(470 nm)
Green LED
(525 nm)
Infrared LED
(870 nm)
Red LED (660 nm)
Power supply voltage 12 to 24 VDC±10%, ripple (p-p) 10% max.
Power consumption
Normally: 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC)
Eco Mode: 720 mW max. (current consumption: 30 mA max. at power supply voltage of 24 VDC)
Digital display not lit: 600 mW max. (current consumption: 25 mA max. at power supply voltage of 24 VDC)
Con-
trol
output
ON/OFF
output
Load current: 50 mA (residual voltage (NPN/PNP): 1 V max.,
Open collector (NPN or PNP output, depending on the model)
Light ON/Dark ON selectable
Monitor
output
---
Load 1 to
5 VDC,
10 kΩ min.
---
Protection circuit
Power supply reverse polarity, Output short-circuit protection, Mutual interference prevention (supported for up to 10
Units)
Re-
sponse
time
Super-high-
speed mode
0.25 ms for operation and reset respectively
0.5 ms for
operation and
reset
respectively
Standard
mode
1 ms for operation and reset respectively
2 ms for
operation and
reset
Super-long-
distance
mode
4 ms for operation and reset respectively
7 ms for
operation and
reset
respectively
Sensitivity setting Teaching or manual method
Func-
tions
Timer func-
tion
OFF-delay timer: 0 to 200 ms, 1 to 20 ms (set in 1-ms units); 20 to 200 ms (set in 5-ms units)
Using Mobile Console: OFF delay, ON delay, or one shot (selectable)
Automatic
power con-
trol (APC)
Fiber-optic current digital
control
--- Fiber-optic current digital control
Zero-reset Negative values can be displayed.
Initial reset Settings can be returned to defaults as required.
Monitor fo-
cus
---
Upper and
lower limits
can be set as
required for
every 100
digital values.
---
Indicators
Operation indicator (orange), 7-segment digital incident level display (red), 7-segment digital incident level percentage
display (red), threshold and excess gain 2-color double bar indicators (green and red), 7-segment digital threshold
display (red)
Display timing Switching between normal/peak-hold/bottom-hold possible
Display orientation Switching between normal/reverse possible
Optical axis adjust-
ment
Optical axis adjustment possible (hyper-flashing function)
Ambient illumination
(receiver side)
Incandescent lamp: 10,000 lx max.
Sunlight: 20,000 lx max.
For dimensions, refer to page 26 to 29.
http://www.ia.omron.com/
6