E3X-DA-N
Twin-output Models
Setting Functions (SET Mode)4
The operating mode for the channel
set with the channel-selection switch
can be changed.
● Area Sensing
Area sensing is possible using the threshold values
for channels 1 and 2.
• If channel 1 is set to L-ON, output turns ON when
the incident level is between the thresholds.
• If channel 1 is set to D-ON, output turns OFF
when the incident level is between the
thresholds.
The result is output to control output 1.
(Control output 2 is always OFF.)
2 s
2 s
2 s
2 s
2 s
Teaching
Setting the operating mode
Changing the operating mode
L-ON
D-ON
Sensing function Displayed as “F.”
Standard
(factory-set)
Area
Super-long distance
Super-high speed
Digital incident level display
Set mode selector to
SET.
OFF
(factory-set)
Peak
Bottom
Timer function Displayed as “t.”
(Factory setting)
200
Flashing setting Displayed as “L.”
OFF
(factory-set)
ON
Hold setting Displayed as “H.”
Display orientation setting
Reversing display
Standard
(factory-set)
Reverse
(Factory setting)
L-ON
D-ON
(Factory setting)
Adjustable in 1-ms units
for 0 to 20 ms and in 5-ms
units for 25 ms or higher.
SET
MODE
TEACH
TEACH
TEACH
TEACH
TEACH
TEACH
TEACH
TEACH
TEACH
MODE
MODE
MODE
MODE
TEACH
TEACHTEACH
TEACH
TEACH
TEACH
CH1 CH2
Changed using the channel-selection switch
Channel 1 Channel 2
B
A
B A
Four types of sensitivity settings are available. Refer to page 22 for
details.
http://www.ia.omron.com/
21