Procedure Description Reference
Scene Editing In the Main Window (layout 0), edit the
measurement flow
.
Register processing items.
Set the properties for each processing
item.
Vision System FH series 3D Robot Vision
Application Construction Guide (Cat.No.
Z446) and Vision System FH/FHV series
User's Manual (Cat.No. Z365)
Click the Data save button. Vision System FH series 3D Robot Vision
Application Construction Guide (Cat.No.
Z446) and V
ision System FH/FHV series
User's Manual (Cat.No. Z365)
↓↑
Testing Execute test measurements.
(In the Main Window (layout 0), click the
Measure button.)
Vision System FH series 3D Robot Vision
Application Construction Guide (Cat.No.
Z446) and V
ision System FH/FHV series
User's Manual (Cat.No. Z365)
Adjust the parameters for each processing
item.
Vision System FH series Processing Item
Function Reference Manual for 3D Robot
V
ision (Cat. No. Z445) and Vision System
FH/FHV series Processing Item Function
Reference Manual (Cat. No. Z341)
Click the Data save button. Vision System FH series 3D Robot Vision
Application Construction Guide (Cat.No.
Z446) and V
ision System FH/FHV series
User's Manual (Cat.No. Z365)
Measuring (Opera-
tion)
In the Main Window (layout 0), click the
Switch layout button, and then select
Main W
indow (Layout 1).
Vision System FH series 3D Robot Vision
Application Construction Guide (Cat.No.
Z446) and Vision System FH/FHV series
User's Manual (Cat.No. Z365)
In the Main Window (layout 1), check the
communications with the PLC.
Vision System FH/FHV series User's Man-
ual for Communications Settings (Cat. No.
Z342)
In the Main Window (layout 1), execute
commands from the PLC, such as meas-
urement trigger commands.
Vision System FH/FHV series User's Man-
ual for Communications Settings (Cat. No.
Z342)
Management and
Analysis
Save and analyze measurement data and
images.
Vision System FH series 3D Robot Vision
Application Construction Guide (Cat.No.
Z446) and V
ision System FH/FHV series
User's Manual (Cat.No. Z365)
2 Overview of FH series
2-6
FH Series Vision System Hardware Setup Manual for 3D Robot Vision (Z436-E1)

Table of Contents

Other manuals for Omron fh series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron fh series and is the answer not in the manual?

Omron fh series Specifications

General IconGeneral
TypeMachine Vision System
SeriesFH Series
Power Supply24 VDC
Storage Temperature-20 to 60°C
Humidity35 to 85% RH (non-condensing)
Image SensorCMOS
Processing SpeedHigh-speed processing
ConnectivityEthernet
I/ODigital I/O
Operating SystemEmbedded OS
I/O PortsEthernet, USB