6-3
Ethernet Interface
Ethernet port of Sensor Controller is used for EtherNet/IP or Serial (Ethernet) communication. The
Ethernet port can be changed depending on Sensor Controller series. Be sure to check the series you
are attempting to use.
6-3-1
FH-5050
Precautions for Safe Use
Use only the cables designed specifically for the product. Use of other products may result in
malfunction or damage of the product.
Always turn OFF the power of the FH-L series Sensor Controller and peripheral devices be-
fore connecting or disconnecting a camera or cable. Connecting the cable with power sup-
plied may result in damage of the camera or peripheral devices.
Since cables to which bending is frequently applied is easily broken, use the robotic cable
type (bending resistant cable) to prevent damages.
Do not apply torsion stress to cables. If not, it may cause damage to cables.
Secure the minimum bending radius of cables. If not, it may cause damage to cables.
Precautions for Correct Use
Check the following items on the communications cables that are used in the network.
- Are there any breaks?
- Are there any shorts?
- Are there any connector problems?
When you connect the cable to the communications connectors on devices, firmly insert the
communications cable connector until it locks in place.
Do not lay the communications cables together with high-voltage lines.
Do not lay the communications cable near devices that generate noise.
Do not lay the communications cables in locations subject to high temperatures or high hu-
midity.
Do not lay the communications cables in locations subject to excessive dirt and dust or to oil
mist or other contaminants.
Ethernet port is 2.
FH-5050
Upper port: Ethernet port for connecting a 3D vision sensor
.
Lower port: Ethernet port for connecting a robot controller.
Cable
Use the camera cable (Ethernet cable FHV-VNBX / FHV-VNLBX: sold separately) to connect to the
3D vision sensor
.
Connect a straight or cross LAN cable.
6 I/O Interface
6-13
FH Series Vision System Hardware Setup Manual for 3D Robot Vision (Z436-E1)
6-3 Ethernet Interface
6
6-3-1 FH-5050

Table of Contents

Other manuals for Omron fh series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron fh series and is the answer not in the manual?

Omron fh series Specifications

General IconGeneral
TypeMachine Vision System
SeriesFH Series
Power Supply24 VDC
Storage Temperature-20 to 60°C
Humidity35 to 85% RH (non-condensing)
Image SensorCMOS
Processing SpeedHigh-speed processing
ConnectivityEthernet
I/ODigital I/O
Operating SystemEmbedded OS
I/O PortsEthernet, USB