is designed so that malfunctioning will not occur within the specifications for vibration and shock. If,
however
, the Controller is to be used in a location in which it will be directly subjected to regular vibra-
tion or shock, then implement the following countermeasures:
• Separate the control panel from the source of the vibration or shock. Or secure the Controller and
the panel with rubber padding to prevent vibration.
• Make the building or the floor vibration-resistant.
• To prevent shock when other devices in the panel such as electromagnetic contactors operate, se-
cure either the source of the shock or the Controller with rubber padding.
Accessibility for Operation and Maintenance
• To ensure safe access for operation and maintenance, separate the Controller as much as possible
from high-voltage equipment and power machinery
.
• Secure the minimum bending radius of the cable. Otherwise the cable may be damaged.
• Consider the physical size of USB memory, or SD memory card as these will be inserted in to the
mounted Sensor Controller.
5 Setup and Wiring
5-19
FH Series Vision System Hardware Setup Manual for 3D Robot Vision (Z436-E1)
5-8 Installation in a Control Panel
5
5-8-1 FH-5050