Command Control
224
FQ2-S/CH User’s Manual
for Communications Settings
114 Parallel
control
OUT1 signal
assignment
4 0: Control signal
1 to 32: OR0 to 31
1001 to 1032: Expression 1 to 32
2001: OR (overall judgement)
2002: BUSY
2003: ERROR
2004: READY
2005: RUN
2006: STG
Specifies whether to use
the signal as a control sig-
nal or to use the signal as a
judgment output (OR indi-
vidual output signal) for
inspection items.
115 Parallel
control
OUT2 signal
assignment
4 0: Control signal
1 to 32: OR0 to 31
1001 to 1032: Expression 1 to 32
2001: OR (overall judgement)
2002: BUSY
2003: ERROR
2004: READY
2005: RUN
2006: STG
Specifies whether to use
the signal as a control sig-
nal or to use the signal as a
judgment output (OR indi-
vidual output signal) for
inspection items.
116 Parallel
control
Input mode 4 0: Standard mode (scene chang-
ing only)
1: Expanded mode
Specifies whether or not to
enable functions other than
scene changing with exter-
nal parallel commands.
117 Parallel
control
LED BUSY 4 0: BUSY
1: RUN
Specifies whether to syn-
chronize the BUSY indica-
tor with BUSY or with RUN.
3 Retry func-
tion
Retry mode 4 0: None
1: Normal retry
2: Exposure retry
3: Scene retry
4: Trigger retry
Specifies the retry mode.
4 Retry func-
tion
Switch order
(scene switch-
ing)
4 0: Auto
1: Fixed
Specifies the scene switch-
ing order for scene chang-
ing retries.
5 Retry func-
tion
Switch order
(target scene)
4 -1: none (termination)
0 to 31: Target scene number
Specifies the target scene
number of the scene
switching
6 Retry func-
tion
Timeout time 4 100 to 9,999 (msec) Scene retry timeout time
201 Parallel
Interface
Sensor
Data Unit
OR output 4 0: OK: ON
1: NG: ON
Specifies the polarity when
the OUT0 output signal is
ON. Overall judgements
are supported.
202 Parallel
Interface
Sensor
Data Unit
Judgment out-
put mode
4 0: Level output
1: One-shot output
Specifies whether output is
one-shot output or level
output.
203 Parallel
Interface
Sensor
Data Unit
OR output
delay time
4 0 to 10,000 Specifies the ON delay
time (x0.1 ms) until output-
ting the signal.
System
data num-
ber
Ty p e Item Data
size
Range Description