Command Control
FQ2-S/CH User’s Manual
for Communications Settings
263
5
Appendices
Details of No-protocol TCP, No-protocol UDP, and No-protocol RS-232C Commands
Details of the commands in this section are described in the command format of no-protocol (TCP).
When using commands in no-protocol (UDP), note the following differences from no-protocol (TCP).
Command format
A delimiter is not necessary in the command format.
Responses
A delimiter is not added.
When the acquired data and OK response are sent in succession, the acquired data and OK response are
sent as separate packets.
Execution Commands
CLRERR
Clear Errors
This command clears the error output status (error output and error indicator).
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
CLRMEAS
Clear Measurement Values
This command clears the measurement values.
<Command Format>
CL
CR
RE RR
Command
Delimiter
CR
OK
Delimiter
CR
ER
Delimiter
CL
CR
RM ASE
Command
Delimiter
FQ2-S_CH_comm.book 263 ペー 01年626 木日 前1時4