Command Control
274
FQ2-S/CH User’s Manual
for Communications Settings
UPDATEREFITEM or URI
Re-register Reference Values (Inspection Item)
This command re-registers the reference value for the specified inspection item based on the previously loaded
image.
The model is not updated.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Inspection item number Specifies the item number of the inspection item that will have its reference values re-reg-
istered. (0 to 31)
Only "0" can be specified with the FQ2-S1 series.
UP
CR
DATERE TEMFI
or
Inspection
item number (2 digits max.)
Delimiter
Delimiter
CR
UR I
Inspection
item number (2 digits max.)
Space
(0x20)
Space
(0x20)
CR
OK
Delimiter
CR
ER
Delimiter