Command Control
322
FQ2-S/CH User’s Manual
for Communications Settings
OUTPUTTRANSSTATE or OTS
Set Communication Output Status
This command sets the output status (allowed/prohibited) for all the communications protocol.
Communications protocols with the output status set to prohibited will no longer output signals after being set
as such.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Communications protocol
status to be set
Specifies the communications protocol status to be acquired.
0: Output prohibited status
1: Output allowed status
OU TTRA
CR
PT
S
U N TATESS
Communications protocol status
to be set (1 digit max.)
Communications protocol status to be set
(1 digit max.)
Command
Space
(0x20)
Delimiter
Delimiter
Command
or
TO
CR
Space
(0x20)
Delimiter
CR
OK
CR
ER
Delimiter
FQ2-S_CH_comm.book 322 ペー 01年626 木日 前1時4