Command Control
FQ2-S/CH User’s Manual
for Communications Settings
323
5
Appendices
PARAALLCOND or PAC
Batch Set Terminal Statuses
Batch sets the ON/OFF status for the all parallel I/O output terminals other than the D terminals (D0 to D15).
• Before executing this command, change the FQ2 execution mode to stop mode with the Set Execution Mode com-
mand.
• If the FQ2 is not in stop mode, some parallel terminals cannot be turned ON or OFF with this command.
Set Execution Mode p.267
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Space
(0x20)
Space
(0x20)
PA AL L CON D
CR
RA
Command
Terminal status
(5 digits max.)
Delimiter
Delimiter
Command Terminal status
(5 digits max.)
or
ACP
CR