Command Control
FQ2-S/CH User’s Manual
for Communications Settings
329
5
Appendices
Load Setting Data Commands
SCNLOAD
This command loads scene data that is stored on the SD card inserted in the Touch Finder.
The source for scene data is the following fixed directory on the SD card.
\Sensor name\SCN
<Command format>
<Response format>
When Processing Is Performed Normally
When Processing Is Not Performed Normally
<Parameter Descriptions>
Do not turn off power to the Vision Sensor until there is a response.
Scene No. Specifies the scene No. to be read (0 to 31)
File name of scene data Specifies the scene data file name you want to load. (64 characters max.)
Only files that have an "SCN" extension can be read.
SCN LOAD
Space (0x20)Space (0x20)
C
R
File name of scene data
Scene No. (2 digits max.)
Important
FQ2-S_CH_comm.book 329 ペー 01年626 木日 前1時4