Command Control
FQ2-S/CH User’s Manual
for Communications Settings
337
5
Appendices
Save Configuration Data Commands
SCNSAVE
This command saves scene data to the SD card inserted in the Touch Finder as a file.
The destination for scene data is the following fixed directory on the SD card.
\Sensor name\SCN
<Command format>
<Response format>
When Processing Is Performed Normally
When Processing Is Not Performed Normally
<Parameter Descriptions>
If the specified file name already exists, this existing file will be overwritten.
Do not turn off power to the Vision Sensor until there is a response.
Scene No. Specifies the scene No. to save (0 to 31).
Scene data file name Specifies the file name when saving.
The file name extension (.scn) can be omitted.
SCNSAVE
C
R
Scene data file name
Scene No. (2 digits max.)
Space (0x20)Space (0x20)