Command Control
FQ2-S/CH User’s Manual
for Communications Settings
409
5
Appendices
Set Camera Parameter: 280F 00501040
Sets the value for the specified camera parameter.
Camera parameter numbers: p. 219
Command Format
Response Format
End Codes
Parameter Descriptions
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
Camera parameter number
(4 bytes)
Setting value
(4 bytes)
28 0F 00501040 3 digits max. Dependent on the
camera parameter
(1,000 times the
actual value)
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F End code 00501040
End code (hex) Description
0000 Command execution ended normally.
FFFF Command execution ended in an error.
Camera parameter num-
ber
*
Specifies the number that corresponds to the camera parameter to be set.
Setting value Specifies the setting value to be set to the camera parameter.
FQ2-S_CH_comm.book 409 ペー 01年626 木日 前1時4