Command Control
410
FQ2-S/CH User’s Manual
for Communications Settings
● Set System Data: 280F 00504010
Sets the value to the specified system data.
System data numbers and details: p. 222
Command Format
Response Format
End Codes
Parameter Descriptions
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
System data number (4 bytes) Setting value
(4 bytes)
28 0F 00504010 3 digits max. Dependent on the
system data
(1,000 times the
actual value)
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F End code 00504010
End code (hex) Description
0000 Command execution ended normally.
FFFF Command execution ended in an error.
System data number* Specifies the number that corresponds to the system data to be set.
Setting value Specifies the setting value to be set to the system data.
FQ2-S_CH_comm.book 410 ページ 2014年6月26日 木曜日 午前11時47分