Appendices
● Load All Calibration Data: 280F 0060B000
This command loads all calibration data that is stored on the SD card inserted in the Touch Finder.
The source for all calibration data is the following fixed directory on the SD card.
\Sensor name\CGP
Format
Response Format
End Codes
Parameter Descriptions
Do not turn off power to the Vision Sensor until there is a response.
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
All scene data file name
(4 to 64 bytes)
28 0F 0060B000 64 characters max.
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F End code 0060B000
End code (hex) Description
0000 Command execution ended normally.
FFFF Command execution ended in an error.
All calibration data name Specifies the all calibration data file name to be loaded.
The file name extension (.cgp) can be omitted.