Command Control
422
FQ2-S/CH User’s Manual
for Communications Settings
Save System Data: 280F 00703000
Saves system data as a file to the SD card inserted in the Touch Finder.
The destination for system data is the following fixed directory on the SD card.
\Sensor name\SYD
Format
Response Format
End Codes
Parameter Descriptions
Do not turn off power to the Vision Sensor until there is a response.
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
System data file
name (4 to 64 bytes)
28 0F 00703000 64 characters max.
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F End code 00703000
End code (hex) Meaning
0000 Command execution ended normally.
FFFF Command execution ended in an error.
System data file name Specifies the system data file name.
The file name extension (.syd) can be omitted.
Important