Command Control
426
FQ2-S/CH User’s Manual
for Communications Settings
Save Calibration Data: 280F 0070A000
This command saves the calibration data with the specified calibration number as a file to the SD card inserted
in the Touch Finder.
The destination for calibration data is the following fixed directory on the SD card.
\Sensor name\CLB
Format
Response Format
End Codes
Parameter Descriptions
If the specified file name already exists, this existing file will be overwritten.
Do not turn off power to the Vision Sensor until there is a response.
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
Calibration
number to save
(4 bytes)
Calibration data
file name
(4 to 64 bytes)
28 0F 0070A000 2 digits max. 64 characters
max.
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F End code 0070A000
End code (hex) Description
0000 Command execution ended normally.
FFFF Command execution ended in an error.
Calibration number Specifies the scene number (0 to 31) to be saved.
Calibration data file
name
Specifies the file name when saving.
The file name extension (.clb) can be omitted.