14
System Configuration Section 1-2
Connection with Network Configurator
The NE1A-series Controller is set and programmed using a Network Configu-
rator. The Network Configurator also enables uploading configuration data,
online monitoring of program execution status, error history checks, etc.
The Network Configurator can be used in the following ways:
• Direct connection to DeviceNet
• USB connection to the NE1A-series Controller
• Serial connection to an OMRON PLC
• Connection from Ethernet using an EtherNet/IP-DeviceNet Router
• Direct connection to EtherNet/IP (for Controllers that support EtherNet/IP)
Direct Connection to DeviceNet
A DeviceNet Board/Card enables the Network Configurator to connect directly
to the network. Remote configuration and monitoring are supported for stan-
dard nodes and safety nodes on the network. When connected directly to
DeviceNet, the Network Configurator forms one node on the network.
Standard PLC
Standard Master
NE1A
Safety Slave
Standard Slave
Downloading/uploading configuration
data and monitoring are supported from
the Network Configurator for devices on
the network via DeviceNet.
Network