3-52
3-7 Parameter List
3
Operation
Options
P036 Torque bias mode
00: None
01: Digital Operator
02: Terminal O2
00 No
4-122
4-123P037 Torque bias value
-200. to +200. (0.4 to 55 kW)
-180. to +180. (75 to 132 kW)
0. Yes %
P038
Torque bias polarity
selection
00: Signed
01: Depends on the RUN direction
00 No
P039
Speed limit value in
torque control
(forward)
0.00 to Maximum frequency 0.00 Yes Hz
4-122
P040
Speed limit value in
torque control
(reverse)
0.00 to Maximum frequency 0.00 Yes Hz
P044 Not used
Use "1.00".
*Do not change.
1.00 No s
P045
Operation setting at
communications error
00: Trip
01: Trip after deceleration stop
02: Ignore
03: Free run
04: Deceleration stop
01 No 
P046
Output assembly
instance No. setting
20
21
100
21 No 
P047
Input assembly
instance No. setting
70
71
101
71 No 
P048
Operation setting at
idle mode detection
00: Trip
01: Trip after deceleration stop
02: Ignore
03: Free run
04: Deceleration stop
01 No 
P049
Polarity setting for
rotation speed
0/2/4/6/8/10/12/14/16/18/20/22/24/26/28/30/
32/34/36/38
0No
P055
Pulse train frequency
scale
1.0 to 50.0 25.0 No kHz
4-138
P056
Pulse train frequency
filter time constant
0.01 to 2.00 0.10 No s
P057
Pulse train frequency
bias amount
-100. to +100. 0. No %
P058
Pulse train frequency
limit
0. to 100. 100. No %
Parameter
No.
Function name Monitor or data range
Default
setting
Changes
during
operation
Unit Page
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001