4-178
4-4 Communication Function
4
Functions
<Holding Register Number List>
<Holding Register Number List (Function Mode)>
1034h
Pulse counter monitor
d028
(HIGH)
R/W
0 to 2147483647 1
1035h
d028
(LOW)
R/W
1036h
Position command monitor
d029
(HIGH)
R
-2147483647 to 2147483647 1
1037h
d029
(LOW)
R
1038h
Current position monitor
d030
(HIGH)
R
-2147483647 to 2147483647 1
1039h
d030
(LOW)
R
103Ah
to
1102h
Not used 
Register
No.
Function name
Function
code
R/W Monitor and setting parameters
Rresolution
Register
No.
Function name
Function
code
R/W Monitor and setting parameters
Resolution
1103h
Acceleration time 1
F002
(HIGH)
R/W 1 to 360000 0.01 [s]
1104h
F002
(LOW)
1105h
Deceleration time 1
F003
(HIGH)
R/W 1 to 360000 0.01 [s]
1106h
F003
(LOW)
1107h
Operator rotation direction
selection
F004 R/W
0: Forward
1: Reverse
1108h
to
1200h
Not used 
Register
No.
Function name
Function
code
R/W Monitor and setting parameters
Resolution
1201h
Frequency reference
selection
A001 R/W
0: Digital Operator (FREQ adjuster)
1: Terminal
2: Digital Operator (F001)
3: ModBus communication
4: Option 1
5: Option 2
6: Pulse train frequency
7: Not used
10: Frequency operation result
1202h RUN command selection A002 R/W
1: Terminal
2: Digital Operator (F001)
3: ModBus communication
4: Option 1
5: Option 2

Table of Contents