Loading...
3-48
3-7 Parameter List
3
Operation
Control parameter
H006
Stabilization
parameter
0. to 255.
100.
Yes 4-118H206
* 2nd stabilization
parameter
100.
H306
* 3rd stabilization
parameter
100.
H020 Motor parameter R1
0.001 to 9.999
10.00 to 65.53
Depends
on the
motor
capacity.
No
4-113
H220
* 2nd motor
parameter R1
Depends
on the
motor
capacity.
H021 Motor parameter R2
0.001 to 9.999
10.00 to 65.53
Depends
on the
motor
capacity.
No
H221
* 2nd motor
parameter R2
Depends
on the
motor
capacity.
H022 Motor parameter L
0.01 to 99.99
100.0 to 655.3
Depends
on the
motor
capacity.
No mH
H222
* 2nd motor
parameter L
Depends
on the
motor
capacity.
H023 Motor parameter Io
0.01 to 99.99
100.0 to 655.3
Depends
on the
motor
capacity.
No A
4-113
H223
* 2nd motor
parameter Io
Depends
on the
motor
capacity.
H024 Motor parameter J
0.001 to 9.999
10.00 to 99.99
100.0 to 999.9
1000. to 9999.
Depends
on the
motor
capacity.
No kgm
2
H224
* 2nd motor
parameter J
Depends
on the
motor
capacity.
Parameter
No.
Function name Monitor or data range
Default
setting
Changes
during
operation
Unit Page
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.