3-33
Param-
eter
No.
MemoChan-
ges
during
opera-
tion
Default
setting
Set-
ting
range
DescriptionNameRegis-
ter No.
(Hex)
n140 018C Energy-sav-
ing control
coefficient K2
Sets the coefficient for the primary
level of energy-saving control.
Note The constant automatically
changes according to the
motor code in n158. Make
fine adjustments of the con-
tact if necessary after setting
the motor code in n158.
0.0 to
6,550
Varies
with the
capac-
ity
No
n141 018D Energy-sav-
ing voltage
lower limit at
60-Hz output
These parameters prevent the out-
put voltage of the Inverter from drop-
ping excessively so that the motor
will not stall or come to a stop at the
primary level of energy-saving con-
trol.
0 to
120
50 No
n142 018E Energy-sav-
ing voltage
lower limit at
6-Hz output
Sets the lower limit of output voltage
as a percentage at each frequency
based on the rated motor voltage as
100%.
Note Normally, the default settings
do not need to be changed.
0 to
25
12 No
n143 018F Power aver-
aging time
Sets the time required to calculate
the average of power used in ener-
gy-saving control.
Power averaging time (ms) = Set
value x 24 (ms)
Note Normally, the default setting
does not need to be changed.
1 to
200
1 No
n144 0190 Probe opera-
tion voltage
limit
Sets the range of voltage control for
the secondary level of energy-saving
control.
Sets the parameter as a percentage
based on the rated motor voltage as
100%.
Note No probe operation is avail-
able with the parameter set to
0.
0 to
100
0 No
n145 0191 Probe opera-
tion control
voltage step
at 100%
Sets the range of probe operation
voltage as a percentage based on
the rated motor voltage as 100%.
Note Normally, the default settin