85
Response Format
@ W#
Unit no. FCS TerminatorHeader
code
Response
code
*s
x 10
0
x 10
1
x 16
1
x 16
0
Parameters Timer/Counter instruction (command): Specify in four letters the instruction
used to create the timer/counter (see below).
Timer/Counter number (command): Specify the timer/counter number used
to define the timer/counter.
Timer/Counter instruction
Instruction Timer/Counter
CPUs)
T I M H HIGH-SPEED TIMER
(TIMH(015))
T T I M ACCUMULATIVE
TIMER (TTIM(120))
C N T R REVERSIBLE
COUNTER (CNTR(012))
T I M space TIMER (TIM)
C N T space COUNTER (CNT)
Note A total of four letters are required to specify the instruction. Be sure to include a
space where necessary.
New SV (command): Specify the new constant SV in four digits of BCD.
5-20 SV CHANGE 2
Finds the specified timer or counter instruction in the program (main program
area) starting from the specified address and changes the constant SV in 4-digit
BCD or the address of the word containing the SV. This command can be used to
specify address in programs only up to 10K words in size.
Note 1. Only the first instruction in the program after the specified address that
meets the specifications will be found.
2. Only the main program will be searched for CVM1 PCs.
3. If the PC is programmed using SFC, only action 0 will be searched. The en-
tire main program will be searched if SFC programming is not used.
Command Format
OP2OP1
@ W$
x 10
0
x 10
1
x 10
0
x 10
1
x 10
2
x 10
3
x 10
0
x 10
1
OP4OP3x 10
2
x 10
3
OP2OP1 x 10
2
x 10
3
x 10
0
x 10
1
OP4OP3
FCS
Unit no.
Terminator
Header code Address Timer/Counter instruction Timer/Counter number
New SVOperand
*s
SV CHANGE 2 Section 5-20