2-1-2 Specifications
Ratings
Parameter Specifications
Supply voltage 100 to 240 VAC, 50/60 Hz
Permissible variation
range of supply voltage
85 to 264 VAC
Power consumption 35 VA max.
Insulation resistance
50 M
min. at 500 VDC between power supply terminals and case; between input/output
terminals and case; between power supply terminals and input/output terminals
Dielectric strength For all combinations given above: 1,500 VAC 50/60 Hz for 1 minute, leakage current: 10 mA
max.
Noise resistance 1,500 Vp-p, pulse width: 100 ns to 1 µs, rise time: 1 ns
Vibration
i
Mechanical 10 to 150 Hz with 0.3-mm double amplitude for 32 minutes in X, Y, and Z directions
resistance
Malfunction 10 to 150 Hz with 0.2-mm double amplitude for 32 minutes in X, Y, and Z directions
Shock resistance 20G, three times in X, Y, and Z directions
Ambient operating
temperature
–10°C to 55°C
Ambient operating
humidity
35% to 85% (without condensation)
Atmosphere With no corrosive gases
Storage temperature –25°C to 65°C
Protection class Class I (with protective conductor terminal)
Protection rating IEC60529: IP30 (built into panel)
Approved standards IEC1010-1, EN61010-1, UL3101, CSA1010.1, FCC Part 15 Subpart B
Weight V600-CA1A-Vj:
890 g
V600-CA2A-Vj:
930 g
Altitude 2,000 m max.
Overvoltage category II
Pollution degree
2
Characteristics
Parameter Specifications
Memory backup Capacitors used for backup, and storage of statistical errors and latest errors are effective for 20
days after Unit power is turned off (at ambient temperature of 25°C). Refer to the plot given below
for the relationship between ambient temperature and memory backup time.
Self-diagnosis
function
Checks CPU errors, memory errors, power cutoff, and communication errors.
Ambient Temperature vs. Memory Backup Characteristics
Ambient
temperature (
°C)
Capacitor backup time (days)

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C