4-3SectionBasic Operations
61
The JOB Key is effective when the MONITOR Mode initial display is shown.
Press
the RESET Key to move from another operation and create the job specifi
-
cation.
1, 2, 3...
1. When
the JOB Key is pressed, “HEAD1” is displayed. If R/W Head 1 is to be
set,
press the SET Key
. If R/W Head 2 is to be set, press the INC/DEC Key
once and then press the SET Key.
2. When the Set Key is pressed, “page0” is displayed.
3. Press the INC Key twice and specify page 2.
4. Press
the SET Key to set the page number
to 2, and then the display chan
-
ges to address/data.
Note 1. The
head number is specified using the INC/DEC Key
. The numerical keys
are not effective.
2. A
page number is the number of a division in the DC memory
area (see page
21).
Page
0
Page 1
Page 7
to
DC memory area
256 bytes
256 bytes
256 bytes
2048 bytes
0000
to
00FF
0100
to
01FF
0700
to
07FF
4-3-3 Address Setting (ADRS)
This
enables the
setting of the start address for data reading, writing, and test
-
ing.
Operation Procedure Start address: 5A in this example
INC INC
DEC
aXXdXX
a5AdXX
a5AdXX
(1)
(2)
(3)
(4)
RESET
ADRS
a5AdXX
5
A
DEC
a5_dXX
a_ dXX

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C