EasyManuals Logo
Home>Omron>Other>V680 Series

Omron V680 Series User Manual

Omron V680 Series
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #175 background imageLoading...
Page #175 background image
Section 7 Message Details
Section 7
Host Communications Specifications
173
RFID System
User's Manual
(Modbus TCP)
COPY DATA
This query uses two Reader/Writers to copy data from the memory of an RF Tag in the
communications field of one Reader/Writer (A) to the memory of the RF Tag in the communications
field of another Reader/Writer (B).
If communication diagnostic is enabled from both Reader/Writers (copy source and copy destination)
when you copy data, the following communications diagnostic results are returned to the host device.
The NORM/ERR indicator in the operation indicators of the source Reader/Writer flashes as shown in
the table below.
To check the communications diagnostic results for the copy destination Reader/Writer, use the Web server for the copy
destination Reader/Writer and check it by itself.
Refer to Web Server in Section 6 Functions for detailed information on Web server function.
p.117
Copy destination
Communications normal
(stable communications):
Indicator lights green.
Communications normal
(unstable communications):
Indicator lights yellow.
Communications failed:
Indicator lights red.
Copy source
Communications normal
(stable communications):
Indicator lights green.
Communications normal
(stable communications):
Indicator lights green.
Communications normal
(unstable communications):
Indicator lights yellow.
Communications failed:
Indicator lights red.
Communications normal
(unstable
communications): Indicator
lights yellow.
Communications normal
(unstable communications):
Indicator lights yellow.
Communications normal
(unstable communications):
Indicator lights yellow.
Communications failed:
Indicator lights red.
Communications failed:
Indicator lights red.
Communications failed:
Indicator lights red.
Communications failed:
Indicator lights red.
Communications failed:
Indicator lights red.
Copy source
Reader/Writer
Switching Hub
PLC
Copy destinatio
Reader/Writer

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V680 Series and is the answer not in the manual?

Omron V680 Series Specifications

General IconGeneral
BrandOmron
ModelV680 Series
CategoryOther
LanguageEnglish

Related product manuals