Section 4 Installation
Section 4
Installation and Connections
RFID System
User's Manual
(Modbus TCP)
75
Connector Cover
V680S-A63
Either use the V680S-A63 Attachment to mount the Connector Cover with screws or permanently
attach the RF Tags with adhesive.
1. Through a cord into a connector cover.
2. Press a connector cover up.
Make the snap-fit sectionbend, and press up.
Insert the protector section of a connector straight.
3. Press a connector cover up until it clicks.
4. 4)Install it together with the RFID reader/writer and V680S-A63.
Tightening torque: 1.2 N·m
Snap-fit Section
Protector Section
M4 screw
Spring washer
Flat washer