13
V700-L21
User's Manual
Section 2
2.1 CIDRW controller: Model V700-L21
Section 2
Unit Specifications
MODE switch
This is a 8-position rotary switch that selects an intended operation mode. Available operation modes
are normal operation mode and setup mode. The controller is factory-set to normal operation mode
(0)
.
* For the information about parameters, refer to Sec. 5.2 "How to set parameters".
RESET switch
Using a pointed tool, depress this switch to reset the CIDRW controller. The controller will be reset to
the original state that is same as a one occurring immediately after powering ON.
MODE SW position Operation mode Function
0 Normal operation mode The controller serves as a CIDRW.
3 Setup mode The operator can set up parameters.*
1, 2, 4, 5, 6, 7 Do not select these positions. Reserved
When the CIDRW controller is powered ON, the mode specified by the MODE switch is
automatically accessed. Remember that changing the MODE switch setting while the controller is
running does not switch over the current operation mode. To enable another operation mode,
power OFF and power ON again the CIDRW controller or press the RESET switch.
• NEVER attempt to select any of the illegal settings 1, 2, 4, 5, 6 and 7.
MODE switch RESET switch
SECSID
MODE
RESET