Section 2
Unit Specifications
■ General specifications
■ 24 V power terminals
The 24 V power terminals include the power terminals and frame ground terminal. Remove the cover,
and make wiring connections. After the wiring work, reinstall the cover.
Characteristic Specification Comment
Supply voltage 24 VDC, +10%, −15% Supplied from the power terminals
Current consumption 150 mA max. Approx. 10 A max. with rush current
Dimensions 150 × 167 × 28 mm Except for protrusions on connectors
Protection class IP20 (per IEC 60529)
Operating ambient
temperature
0 to +40°C No freezing
Operating ambient
humidity
10 to 85%RH No dew condensation
Storage ambient
temperature
-15 to +65°C No freezing
Storage ambient
humidity
10 to 95%RH No dew condensation
Mounting system Secured with four M4 screws. Use the enclosed washers.
• Recommended 24 V power supply:
Model S82K-03024 (OMRON)
• For wiring connections, use compression
rings.
• Use the M3 compression rings illustrated
below.
Wrong wiring connection can lead to a malfunction of the equipment. Be fully sure of the correct
wiring connections.
24 VDC
GR (frame ground)
6 mm max.
6 mm max.