64
Section 5
5.2 How to set up parameters
V700-L21
User's Manual
Section 5
Setup Mode
To set up a parameter, send the following instructions from the terminal software.
First, select the tag name of a parameter being altered and enter a setting value to complete [parameter
definition]. Then, perform [parameter change]. To be able to alter two or more parameters, repeat [parameter
definition] process the necessary number of times, and then execute [parameter change]. After completion of
a setup process, a message and ERROR status indicator indicate the result (success or failure).
Status after setup process
: Lit, : Unlit
After successful completion of setup process, restart the CIDWR controller. As a result, the newly defined
parameters will become valid. To restart, either power OFF and ON again or execute [Reset] command
("::EXIT").
To view the contents of parameters, execute [parameter output] command. All the currently valid parameter
values will be displayed.
Instruction Format Action
Parameter definition "(Tag name)" + "=" + "(setting value)" + CR + LF Enter the parameter for the tag name.
Parameter change "::END" A so far received parameter definition is checked. If
the definition is found to be valid, the parameter set-
ting is altered accordingly.
Comment "#" + "(Comment)" + CR + LF or CR + LF This line is ignored as a comment line.
Parameter output "::GET_PARAM" A predefined parameter is output.
Reset "::EXIT" CIDRW controller is repowered.
Normal completion "SETUP_COMPLETE" ERROR The selected parameter was altered as intended.
The values of parameters not specified remain unchanged.
Setup failure "SETUP_FAILED [2]" ERROR An error situation is present. The value of any parameter
remains unchanged. The value in [ ] represents a line where a
first error has been detected. If a parity error is contained in a
received character string, this value will be 0.