65
V700-L21
User's Manual
Section 5
5.2 How to set up parameters
Section 5
Setup Mode
[Parameter setup example]
➀
Link the CIDRW controller to the upstream controller, and boot up the terminal software. Then,
power UP the CIDRW controller in setup mode.CIDRW
➁
For a parameter being altered, execute parameter definition.
Once a first parameter is defined, the ALARMS status indicator flashes.
➂
Execute parameter change process. The entered parameter is checked and written into the CIDRW
controller.
➃
Once setup process is complete, a message indicating the result appears.
The ALARMS status indicator stably lights.
➄
Once the whole setup procedure is successfully complete, restart the CIDRW controller in normal
operating mode.
It will be convenient to create a text file such as a one shown below and transmit the file using the text
file send function of the terminal (upstream controller).
Prm.txt
SETUP_START <L21 ><XXX.XX,YYY.YY>
_
SETUP_START <L21 ><XXX.XX,YYY.YY>
S_BAUD=19200 [ENTER]
S_DEVID=1 [ENTER]
S_BNO=0 [ENTER]
_
* [ENTER] does not appear on
the screen.
SETUP_START <L21 ><XXX.XX,YYY.YY>
S_BAUD=19200
S_DEVID=1
S_BNO=0
::END [ENTER]
* [ENTER] does not appear on
the screen.
SETUP_START <L21 ><XXX.XX,YYY.YY>
S_BAUD=19200
S_DEVID=1
S_BNO=0
::END
SETUP_COMPLETE
_
#Parameter Setting File for SystemA
#Protocol
S_BAUD=19200
S_DEVID=1
#SECS
S_BNO=0
::END