65
V700-L21
User's Manual
Section 5
5.2 How to set up parameters
Section 5
Setup Mode
[Parameter setup example]
Link the CIDRW controller to the upstream controller, and boot up the terminal software. Then,
power UP the CIDRW controller in setup mode.CIDRW
For a parameter being altered, execute parameter definition.
Once a first parameter is defined, the ALARMS status indicator flashes.
Execute parameter change process. The entered parameter is checked and written into the CIDRW
controller.
Once setup process is complete, a message indicating the result appears.
The ALARMS status indicator stably lights.
Once the whole setup procedure is successfully complete, restart the CIDRW controller in normal
operating mode.
It will be convenient to create a text file such as a one shown below and transmit the file using the text
file send function of the terminal (upstream controller).
Prm.txt
SETUP_START <L21 ><XXX.XX,YYY.YY>
_
SETUP_START <L21 ><XXX.XX,YYY.YY>
S_BAUD=19200 [ENTER]
S_DEVID=1 [ENTER]
S_BNO=0 [ENTER]
_
* [ENTER] does not appear on
the screen.
SETUP_START <L21 ><XXX.XX,YYY.YY>
S_BAUD=19200
S_DEVID=1
S_BNO=0
::END [ENTER]
* [ENTER] does not appear on
the screen.
SETUP_START <L21 ><XXX.XX,YYY.YY>
S_BAUD=19200
S_DEVID=1
S_BNO=0
::END
SETUP_COMPLETE
_
#Parameter Setting File for SystemA
#Protocol
S_BAUD=19200
S_DEVID=1
#SECS
S_BNO=0
::END