6 Programming Features
109
Constants Requiring Restrictions
Con-
stant
No.
Name Description Fac-
tory
Set-
ting
n023 S-curve Selection 0: No S-curve Characteristic
1: 0.2-s S-curve Characteristic
2: 0.5-s S-curve Characteristic
3: 1.0-s S-curve Characteristic
Note: S-curve characteristics are not
supported for simple position-
ing control, so use a set value
of 0.
0
n092 Stall Prevention dur-
ing Deceleration
0: Stall prevention
1: No stall prevention (when a brak-
ing resistor is installed)
Note: If Stall Prevention during De-
celeration is used with simple
positioning control, position-
ing will not be performed prop-
erly, so use a set value of 1.
0