6 Programming Features
117
If n045 > 0 the frequency reference is changed in steps of n045 value
For n045=0, acceleration / deceleration rate is selected by n046:
n046 = 0: Accel/Decel time 1 time (n019 / n020)
n046 = 1: Accel/Decel time 4 (n043 / n044)
Saving of the Up/Down 2 bias to the EEPROM if save mode n100=1 is
selected (Frequency reference has to remain for 5 sec)
S6
Fref
S7
n045
Reference changes
according to setting in n045
S6
S7
Fref
Deceleration rate,
sel. by n046
Acceleration rate ,
sel. by n046
n100 = 1
5 sec
5 sec
Up 2/ Down 2 bias is saved,
when Run signal is removed
Up 2/ Down 2 bias is not saved,
when Run signal is removed
S6
S7
Fref