244
Note: 1. Not initialized by constant initialization.
2. Upper limit of setting range and factory setting are doubled for 400 V
Class.
3. Depends on Inverter capacity. Refer to the next page.
4. Depends on Inverter capacity. Refer to page 96.
5. Factory setting of the model with JVOP-140 Digital Operator (with
potentiometer) is 0. Setting can be set to 1 by constant initialization.
6. When control mode selection (n002) is changed, factory setting corre-
sponds to the control mode. Refer to the next page.
7. Constant that is provided for 5.5 kW and 7.5 kW Inverters of 200 V
and 400 V Classes.
8. 1 (Enabled) for 5.5 kW and 7.5 kW Inverters of 200 V and 400 V
Classes.
9. Do not select 3 to 100 as they are reserved for future use.
173 01AD DC Injection Braking
Proportional Gain
1 to 999 1 = 0.001 83
(0.083)
No -
174 01AE DC Injection Braking Integral
Time Constant
1 to 250 1 = 4 ms 25 (100
ms)
No -
175 01AF Reducing Carrier Frequency
Selection at Low Speed
0, 1 - 0
(Note 8)
No 97
176 01B0 Constant Copy Function
Selection
rdy, rEd, CPy,
vFy, vA, Sno
-rdyNo 168
177 01B1 Constant Read Selection
Prohibit
0, 1 - 0 No 169
178 01B2 Fault History Stores, dis-
plays most
recent 4
alarms
Setting
disabled
-No 49
179 01B3 Software Version No. Displays
lower-place 4
digits of soft-
ware No.
Setting
disabled
-No -
No. Register
No. for
Trans-
mission
Name Setting Range Setting Unit Factory
Setting
Change
during
Opera-
tion
User
Set-
ting
Ref.
Page