Section 3 SETUP
ZFV
User’s Manual
Section 3
Adjusting Threshold Values
CHARA 1
CHARA 2
Setting item Range Details of Adjustment
Density distribution
value
0 to 100 This is the value that is judged as OK when the density deviation
value during teaching is taken to be 100%.
Setting item Range Details of Adjustment
Correlation value 0 to 100 This is the lower limit of the correlation value with the teaching model.
This value or above is judged as OK.
Adjustment of correlation value
UP/DOWN keys: Change values.
Density distribution value
Measured value
Switch to ADJ Mode.
Adjustment of correlation value
UP/DOWN keys: Change values.
Correlation value
Measured value
Switch to ADJ Mode.