Section 3 SETUP
Section 3
Adjusting Threshold Values
57
ZFV
User’s Manual
■ POSITION
■ COUNT
Setting item Range Details of Adjustment
Position 0 to 468 Amount of shift from reference position
Edge level 0 to 100 This is the level of change in density judged to be an edge.
Adjust this level when measurement is unstable.
p.56
Setting item Range Details of Adjustment
Number 0 to 255 This is the number of times that counting is to be performed.
Edge level 0 to 100 This is the level of change in density judged to be an edge.
Adjust this level when measurement is unstable.
p.56
●Adjustment of edge position
Measured
value
●Adjustment of edge level
Amount
of shift
Amount
of shift
Edge level
UP/DOWN keys: Change values.
Edge level
●Switch to ADJ Mode.
• When edge detection direction is
UP/DOWN keys: Change values.
• When edge detection direction is
LEFT/RIGHT keys:Change values.
●Adjustment of number
UP/DOWN keys: Change values.
Edge level
●Adjustment of edge level●Switch to ADJ Mode.
Measured
value
Lower
limit
Upper