STAND: 17.06.2019 9910_Operation_Manual_STANDCONTROL_C1_Rev1v1_EN Seite 37 von 41
14 Technical data
The technical data of the STAND.CONTROL C1:
Rated input voltage 100 - 240 V
Rated input frequency 50 – 60 Hz
Rated input current consumption 2.5 A
Rated input power 250W
Standby power at nominal voltage,
primary (typical)
0.3 W
Rated output voltage 31 V
dimensions (L x B x H) 294 x 89 x 38 mm
11.57” × 3.50” × 1.50”
weight 0.54 kg
Environmental conditions during transport and
storage
-25 °C to +70 °C at 5 % to 90 % relative atmos-
pheric humidity (non-condensing), with +38 °C
max. dew point;
Temperatures from +55 °C to +70 °C only for
maximum 24h
Environmental conditions in operation +5 °C to +40 °C at 10 % to 85 % relative atmos-
pheric humidity (non-condensing), with +27 °C
max. dew point;
Protection class II
IP class (protection class as per EN 60529) IP 20
Max. duty cycle 2 min. ON / 18 min. OFF (after 2 min. OFF, there
are 17 s ON available)
connections 2x RJ45-socket
2x 8-pole motor connection
1x non-heating connection for power supply