FT
-
3500 ELECTROMAGNETIC FLOW METER
ONICON Incorporated 727.447.6140 Page 31 onicon.com
Access this screen by selecting the home
button in the lower-right corner of the screen.
Main Screen Page
The Main display shows:
Flow rate: Calculated volumetric ow rate based on the pipe size selected and velocity measured.
Volume total: Calculated volumetric total based on the pipe conguration selection and meter mode. If the mode is
bidirectional, the meter will display forward volume or reverse volume depending on the ow direction.
Units: The Main Screen will display the units selected under Main Menu->Preference->Units.
Multiplier: The FT-3500 will auto-select the multiplier based on the full scale of the meter.
Velocity Gage: The Main Screen will display the measured velocity in the selected units. The green section is up to 10ft/s.
The yellow section is 10-17ft/s. The red section is 17-20ft/s.
Mode Indication: The FT-3500 will indicate the ow mode status based on the selection under Main Menu->Meter
Mode->Mode. If bidirectional is selected, the main screen will show Forward vs Reverse ow depending on the direction
of the measured ow. If the mode is selected as single, the meter will show forward mode in normal condition and will go
to an alarm if it is on reversed ow.
Date and Time: The Main Screen will display the saved date and time.
From the main display page, the user can access the main menu and alerts, and displays the locked or unlocked status.
The meter will be unlocked by default, go to Main Menu->Preference->Password to activate and set a password. Refer to
page 30 for the Main Screen icons.