FT
-
3500 ELECTROMAGNETIC FLOW METER
ONICON Incorporated 727.447.6140 Page 48 onicon.com
5.3 START-UP AND COMMISSIONING WORKSHEET
Please read all installation (Sec 3) and commissioning (Sec 4) instructions carefully prior to proceeding with these steps.
Use the following worksheet for checking o the commissioning steps and recording measured values. The following
steps require ow in the pipe. Flow signal readings should be taken while holding the ow rate constant, if possible.
Otherwise, take the various output readings as quickly as possible.
STEP TEST/MEASUREMENT S/N: _________ S/N: ________ S/N: ________ S/N: _________
1. Meter location:
2. Conrm pipe size: ___________ ___________ ___________ ___________
3. Insertion depth and
orientation:
4. Control system
programming:
5. Match display or Btu
meter serial number
(S/N):
___________ ___________ ___________ ___________
6. Signal connections
veried:
7. Supply voltage veried: ___________ ___________ ___________ ___________
8. Connect power:
The following steps require ow in the pipe. Flow signal readings should be taken while holding the ow rate con-
stant if possible, otherwise, take the various output readings as quickly as possible.
9. Frequency output(s):
Avg = green
Average frequency (Hz):
Average frequency (VDC):
Calculated ow rate:
___________Hz
_________VDC
_________GPM
___________Hz
_________VDC
_________GPM
___________Hz
_________VDC
_________GPM
___________Hz
_________VDC
_________GPM
10. Analog or pulse output(s)
4-20 mA signal:
2-10, 1-5, 0-10 or
0-5VDC Signal
(select one):
Scaled output interval:
Calculated ow rate:
___________mA
_________VDC
_____________
_________GPM
___________mA
_________VDC
_____________
_________GPM
___________mA
_________VDC
_____________
_________GPM
__________mA
_________VDC
_____________
_________GPM
11. Flow rate displayed
by control system:
_________GPM _________GPM _________GPM _________GPM

Other manuals for Onicon FT-3500