EasyManua.ls Logo

Opticon NLV-4001 - 8 Technical Specifications; 8.1 Bar Code Test Sample

Opticon NLV-4001
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NLV-4001
2nd
10
SPECIFICATIONS MANUAL
Technical Specifications
8
The conditions for technical specifications are as follows unless otherwise specified in each section.
<Conditions>
Temperature and humidity
Room temperature, room humidity
Illumination LED
ON
Ambient light
300 to 500 lx
Bar codes
Refer to Section 8.1.
Power supply voltage
Rated voltage 5.0 V
Reading test
1 read in 0.5 sec or less.
Accept the performance with 10 consecutive successes.
8.1 Bar Code Test Sample
<Code 39>
Resolution
Symbology
PCS
Quiet Zone
(mm)
No. of Digits
1.0 mm
Code 39
0.9
25 mm
1
0.5 mm
18 mm
3
0.25 mm
10 mm
8
0.2 mm
10 mm
31
0.15 mm
7 mm
10
0.127 mm
5 mm
4
0.076 mm
5 mm
20
<JAN>
Resolution
Symbology
PCS
Quiet Zone
(mm)
No. of Digits
0.26 mm
JAN
0.9
10 mm
13
0.26 mm
10 mm
8
0.33 mm
10 mm
13
0.26 mm
0.3
10 mm
13

Table of Contents