OPTIMUM
MASCHINEN - GERMANY
Safety
Version 1.1.5 dated 2015-08-31Page 14 Original operating instructions
BF30VarioGB
1.9.4 Separating protective equipment
Adjust the protective equipment to the
correct height before you start working.
To do so, detach the clamping screw,
adjust the required height and re-tighten
the clamping screw.
A switch is integrated in the fixture of the
spindle protection which monitors that
the cover is closed.
INFORMATION
You cannot start the machine if the spin-
dle protection is not closed.
Img.1-5: Separating protective equipment
1.10 Safety check
Check the drilling-milling machine in regular intervals.
Check all safety devices
before each operation,
once a week (with the machine in operation),
after every maintenance and repair work.
General check
Equipment Check OK
Protective covers Mounted, firmly bolted and not damaged
Signs,
Markings
Installed and legible
Functional check
Equipment Check OK
EMERGENCY STOP impact
switch
When the EMERGENCY-STOP button is activated, the drilling-milling
machine should switch off. Make sure that it is only possible to restart
the machine if the EMERGENCY STOP push button is unlocked and the
ON switch was activated.
Separating safety device
around the drilling and mill-
ing spindle
The drilling-milling machine may switch on only when the safety device
is closed.