COMPACT version 5.2.002 ENG
Modular audio matrix
with IP connection
COMPONENT
GENERATING THE
ALARM
C ["n":"p" ]
(n= Number of
slave, id.)
If the value is 0,
the unit is a
COMPACT)
(p= Slot occupied by
the card)
The unit "n" incorporates a card in slot
"p" that does not appear in the
configurations of the installation.
Use the Call Point software to add the
unit to the installation tree.
or
remove the card from the COMPACT or
COMPACT-E chassis
When monitoring the speaker line of the
indicated zone, the system detects a low
impedance error.
The impedance in the speaker line has
changed. Inspect said line and check the
status of the speakers.
If the status of the line is correct, you can
adjust the monitoring of the line and
expand the tolerance margin for
detecting the error.
When monitoring the speaker line of the
indicated zone, the system detects a
high impedance error.
The impedance in the speaker line has
changed. Inspect said line and check the
status of the speakers.
If the status of the line is correct, you can
adjust the monitoring of the line and
expand the tolerance margin for
detecting the error.
Check the operation of the amplifier
When monitoring the speaker line of the
indicated zone, the system detects a
short-circuit in the line.
Inspect that speaker line.
If the status of the line is correct, you can
adjust the monitoring of the line and
expand the tolerance margin for
detecting the error.
When monitoring the speaker line of the
indicated zone, the system detects an
open line error.
Inspect that speaker line.
If the status of the line is correct, you can
adjust the monitoring of the line and
expand the tolerance margin for
detecting the error.