13. CARACTERÍSTICAS TÉCNICAS
Slots
10
Ethernet communication
2 Ethernet connections (RJ45) A and B for redundant installations. IP Layer 3 & Layer 4
Network.
CAN Bus
Communication with the expansion matrix and peripherals.
Communication speed with slave unit: 500 kbit/s
Communication speed with peripherals: 33.333 kbit/s
VoIP
SIP RFC3261 protocol.
G711 coding (PCMA and PCMU), G722 and L16.
Input contacts
3 Input contacts on the control module. Configurable NC/NO. May be monitored.
The detection time of the activation pulse of the input contacts is configurable
through the Call Point software (0-50-100-200-300-400-500-1000-1500-2000
milliseconds).
Output contacts
3 Output contacts on the control module. Configurable NC/NO. Dry contacts or
referenced to ground. Max. DC charge current: 150 mA. Max. DC or AC peak charge
voltage: 350 V.
1 FAIL relay. Max. DC charge current: 150 mA. Max. DC or AC peak charge voltage: 350 V.
Audio inputs
1 Front USB 2.0 as music input. DC output: 5V / 0.2A. Supports wav, mp3 and OGG files.
Internal audio channels
16
SD memory for pre-recorded messages
16 GB
Power supply
24 VDC. Dual power supply (primary and secondary).
Consumption
730 mA (without cards).
Weight
8.5 kg
Finishes
RAL9005 iron painted black.
Measurements
482.6 (width) x 133 (height) x 280 (depth)
Rack units
3