EasyManuals Logo

optris Xi 80 User Manual

optris Xi 80
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
Technical Data 17-
2.3 Measurement specifications
Xi 80
Xi 400
Xi 410
Temperature ranges
-20...100 °C; 0...250 °C;
(20) 150...900 °C
1)
20...100 °C; 0...250 °C;
(20) 150...900 °C
1)
Option: 200…1500 °C
20...100 °C; 0...250 °C;
(20) 150...900 °C
1)
Spectral range
8 - 14 µm
Detector
UFPA,
80 x 80 pixel @ 50 Hz
UFPA,
382 x 288 pixel @ 80 Hz/ 27 Hz
UFPA,
Ethernet: 384 x 240 Pixel @ 25 Hz
USB: 384 x 240 Pixel @ 4 Hz
Lenses (FOV)
12° x 12° (F=1,0); 30° x 30° (F=0,9);
55° x 55° (F=0,9); 80° x 80° (F=0,9)
18° x 14° (F=1,1); 29° x 22° (F=0,9);
53° x 38° (F=0,9); 80° x 54° (F=0,9)
18°x12° (F=1,1), 29°x18° (F=0,9),
53°x31° (F=0,9), 80°x44° (F=0,9)
Microscope lens (FOV)
-
18° x 14° (F=1,1, minimum spot size:
81 µm @ 90 mm, working distance:
90-110 mm)
-
Optical resolution
190:1 (12° optic)
390:1 (18° optic)
System accuracy
2)
±2 °C or ±2 %
Thermal sensitivity (NETD):
100 mK
80 mK