Other CRUs
Removal and Replacement 3-33
To Prepare the Base Module CRU for Replacement
1. Grasp the base module chassis by the sides and remove it from the shipping
carton.
2. Determine if the CRU is the bottom library module. If it is the bottom module,
install the floor (see "To Install the Floor" on page 3-27).
To Replace the Base Module Chassis
Task 1 Install the CRU
1. Grasp the base module along the side and lift it until the back is above the rack
rails.
2. Guide the module into the rack and set the rear side-tabs on the rack rails (see
Figure 3–32).
Figure 3–32 Base Module Side Tabs
Illustration Legend:
1-FrontTab
2 - Center Tab
3-BottomTab
4 - Rear Tab
3. Push the module into the rack to engage the bottom and center side-tabs.
Note: If you cannot engage the rails properly, remove the base
module and adjust the rails. Never bend the tabs to engage a rail.
4. Push the module into the rack until the front side-tabs approach the front of the
rack rails.
5. Lift the module up slightly, push it into the rack, and set the front tabs down on
the rack rail.

Table of Contents

Other manuals for Oracle storagetek sl150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle storagetek sl150 and is the answer not in the manual?

Oracle storagetek sl150 Specifications

General IconGeneral
BrandOracle
Modelstoragetek sl150
CategoryStorage
LanguageEnglish

Related product manuals