Loading...
Setting contents of MEXE02
−61−
Setting of operation data using "Analog input signal selection" parameter
The setting method of operation data can be changed using the "Analog input signal selection" parameter.
Combinations of the mode number and analog setting/digital setting are shown in the table below. Others except the
following combinations are not available to set.
Mode No.
Operation
data No.
VR1 VR2 VR3
External
potentiometer
Digital setting
Mode 0
(initial
setting)
0 Rotation speed
Acceleration/
Deceleration time
Torque limiting value
1
Acceleration/
Deceleration time
Torque limiting value Rotation speed
2 - 7
Rotation speed
Acceleration time
Deceleration time
Torque limiting value
Mode 1 0 - 7
Rotation speed
Acceleration time
Deceleration time
Torque limiting value
Mode 2 0 - 7 Torque limiting value
Rotation speed
Acceleration time
Deceleration time
Mode 3
0 Acceleration time Deceleration time Rotation speed Torque limiting value
1 Acceleration time Deceleration time Rotation speed Torque limiting value
2 - 7
Rotation speed
Acceleration time
Deceleration time
Torque limiting value
Mode 4
0 Rotation speed Torque limiting value
Acceleration/
Deceleration time
1 Torque limiting value
Acceleration/
Deceleration time
Rotation speed
2 - 7
Rotation speed
Acceleration time
Deceleration time
Torque limiting value
Mode 5
0 Torque limiting value
Acceleration/
Deceleration time
Rotation speed
1 Torque limiting value
Acceleration/
Deceleration time
Rotation speed
2 - 7
Rotation speed
Acceleration time
Deceleration time
Torque limiting value
Note
The torque limiting potentiometer (VR3) is set to the maximum value at the time of shipment. When
selecting the mode Nos. 3 to 5, check the setting value before operating a motor because the rotation
speed and acceleration/deceleration time are set to the maximum value initially.
"Operation input mode selection" parameter
Input of operation signal can be switched between 2-wire mode and 3-wire mode.
The operation input mode is a method to select the motor rotation direction and operation signal. The motor is
operated using the FWD input and REV input in 2-wire mode. In 3-wire mode, the motor is operated using the START/
STOP input, RUN/BRAKE input, and the FWD/REV input.
In each operation input mode, signal functions will be changed as follows.
2-Wire mode 3-Wire mode
FWD input START/STOP input (ON: Operation, OFF: Deceleration stop)
REV input RUN/BRAKE input (ON: Operation, OFF: Instantaneous stop)
STOP-MODE input
FWD/REV input
(OFF: Rotates in clockwise direction, ON: Rotates in counterclockwise direction)
Note
When the electromagnetic brake type motor is used in vertical drive such as elevating equipment, set the
operation input mode to 2-wire mode. If the RUN/BRAKE input is turned OFF or the FWD/REV input is switched
in the 3-wire mode, the moving part may fall. Also, use the motor in a state where the STOP-MODE input is
being ON. If the STOP-MODE input is in an OFF state, the moving part may fall when the motor stops.