Setting contents of MEXE02
−58−
11.4 I/O function selection
A: Update immediately, B: Update after operation stop, C: Update after executing conguration
Parameter name Description Setting range Factory setting Update
X0
Selects the functions to
assign to the X0 to X5.
Not used
FWD (START/STOP)
*∗
REV (RUN/BRAKE)
*∗
STOP-MODE (FWD/REV)
*∗
MB-FREE, EXT-ERROR
ALARM-RESET
HMI, M0, M1, M2
FWD (START/STOP)
*
B
X1 REV (RUN/BRAKE)
*
X2 STOP-MODE (FWD/REV)
*
X3 M0
X4 ALARM-RESET
X5 MB-FREE
Y0
Selects the functions to
assign to the Y0 and Y1.
Not used
ALARM-OUT1, WNG, MOVE
TLC, VA, ALARM-OUT2, DIR
ALARM-OUT1
A
Y1 WNG
NET-IN0 input function selection
Selects the functions to
assign to the remote I/O
input signals (NET-IN0 to
NET-IN15).
Refer to the USER
MANUAL (RS-485
Communication Mode)
for remote I/O.
Not used
FWD (START/STOP)
*∗
REV (RUN/BRAKE)
*∗
STOP-MODE (FWD/REV)
*∗
MB-FREE, HMI, M0, M1, M2
M0
C
NET-IN1 input function selection M1
NET-IN2 input function selection M2
NET-IN3 input function selection FWD (START/STOP)
*
NET-IN4 input function selection REV (RUN/BRAKE)
*
NET-IN5 input function selection STOP-MODE (FWD/REV)
*
NET-IN6 input function selection Not used
NET-IN7 input function selection MB-FREE
NET-IN8 input function selection Not used
NET-IN9 input function selection Not used
NET-IN10 input function selection Not used
NET-IN11 input function selection Not used
NET-IN12 input function selection Not used
NET-IN13 input function selection Not used
NET-IN14 input function selection Not used
NET-IN15 input function selection Not used
NET-OUT0 output function selection
Selects the functions to
assign to the remote I/
O output signals (NET-
OUT0 to NET-OUT15).
Refer to the USER
MANUAL (RS-485
Communication Mode)
for remote I/O.
Not used
FWD_R (START/STOP_R)
*
REV_R (RUN/BRAKE_R)
*
STOP-MODE_R (FWD/REV_R)
*
MB-FREE_R, HMI_R, M0_R
M1_R, M2_R, ALARM-OUT1
WNG, MOVE, TLC, VA, S-BSY
ALARM-OUT2, MPS, DIR
M0_R
NET-OUT1 output function selection M1_R
NET-OUT2 output function selection M2_R
NET-OUT3 output function selection FWD_R (START/STOP_R)
*
NET-OUT4 output function selection REV_R (RUN/BRAKE_R)
*
NET-OUT5 output function selection STOP-MODE_R (FWD/REV_R)
*
NET-OUT6 output function selection WNG
NET-OUT7 output function selection ALARM-OUT1
NET-OUT8 output function selection S-BSY
NET-OUT9 output function selection Not used
NET-OUT10 output function selection Not used
NET-OUT11 output function selection Not used
NET-OUT12 output function selection ALARM-OUT2
NET-OUT13 output function selection MOVE
NET-OUT14 output function selection VA
NET-OUT15 output function selection TLC
*
If the 3-wire mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( ) will be applied.