Setting contents of MEXE02
−60−
11.5 Alarm and warning
A: Update immediately, C: Update after executing conguration
Parameter name Description Setting range Factory setting Update
Undervoltage alarm latch
Switches whether to enable or disable the
retaining state of the undervoltage alarm
function.
If it is set to "Disable," the undervoltage
alarm will automatically be cleared when the
main power supply voltage returns to the
undervoltage detection level or more.
Disable
Enable
Disable C
Undervoltage warning level
Sets the warning level for the undervoltage
of the main power supply.
0.0 to 48.0 [VDC]
24 VDC type: 21.6
48 VDC type: 43.2
A
Undervoltage warning
function
Switches whether to enable or disable the
undervoltage warning function.
Disable
Enable
Enable
Overload warning level
Sets the warning level for the load torque of
the motor.
50 to 100 [%] 100
Overload warning function
Switches whether to enable or disable the
overload warning function.
Disable
Enable
Enable
11.6 Test operation and display
A: Update immediately, D: Update after turning on the power again
Parameter name Description Setting range
Factory
setting
Update
JOG operation speed
Sets the rotation speed of JOG operation for the
data setter
OPX-2A
.
0, 80 to 1000 [r/min] 300
A
JOG operation torque
Sets the torque limiting value of JOG operation
for the data setter
OPX-2A
.
0 to 200 [%] 200
Data setter speed
display
Sets the display method of operating speed in
the monitor mode.
If it is set to "Signed," "-" is displayed when the
motor rotates in the reverse input direction.
Signed
Absolute value
Signed
Data setter edit
Switches whether to enable or disable the
following editing functions.
•
Clear of the alarm and warning histories in the
monitor mode
•
Change of the setting value in the data mode
and parameter mode
•
All operation in the copy mode
Disable
Enable
Enable D
11.7 Operation setting
C: Update after executing conguration, D: Update after turning on the power again
Parameter name Description Setting range Factory setting Update
Data setter initial display
Selects the initial screen when the
driver power is turned on.
Operating speed
Conveyor transfer speed
Load factor
Operation data number
Top screen of monitor mode
Operating speed D
Analog input signal
selection
The setting method of operation data
can be changed.
Mode 0 to 5 Mode 0
C
Prevention of operation
at power-on alarm
function
Switches whether to enable or disable
the prevention of operation at power-
on alarm.
Disable
Enable
Disable
Electromagnetic brake
action at alarm
Sets the timing to activate the
electromagnetic brake when an alarm
is generated.
When setting to "Hold after coasting
to a stop," the electromagnetic brake
will activate and hold the position
after the motor coasts to a stop.
Hold after coasting to a stop
Hold immediately
Hold immediately
Operation input mode
selection
Switches operation signals of external
input between the 2-wire mode and
3-wire mode.
2-Wire mode
3-Wire mode
2-Wire mode